{"title":"Wires \u0026 Cables","description":"\u003cp\u003eFind a complete selection of wire and cable designed for power supply, distribution, and control circuits. This range brings together the industry’s most specified conductors: single building wire (T90, NMD90), armored cable for demanding environments (BX, AC90, TECK90), and equipment wire (TEW). Available in a wide variety of AWG gauges, ratings, and insulation types, these products comply with strict Canadian Electrical Code standards to ensure safety and long-term performance.\u003c\/p\u003e","products":[{"product_id":"cable-electrique-acwu90-4-c-1-0-awg-600-v-noir-acwu4c1-0-wire-acwu4c1-0","title":"Electrical Cable ACWU90 4 C 1\/0 AWG 600 V Black ACWU4C1\/0","description":"ARMOURED CABLE FOR COMMERCIAL, INDUSTRIAL \u0026 APARTMENT USE\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5811 01\u003cbr\u003eFour aluminum conductor material (ACM) conductors with low temperature EXELENE* cross-linked polyethylene insulation (RW90 XLPE) and bare copper bonding wire. Conductor assembly paper wrapped. Rated 600 volts. LEAD FREE and RoHS compliant. Limited Smoke Zero Halogen - CSA rated ST1 per CSA 22.2 No. 2556. Meets the FT4 flame spread test.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eFor open and concealed wiring in dry locations only.\u003cbr\u003eFor use in cabletroughs and ventilated flexible cableways in dry locations only.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C. Approved for use with ceiling fixtures.\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Aluminum\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971809501295,"sku":"WIRE-ACWU4C1\/0","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/0_1_20-_202054d195-eed1-46fe-be67-1322af00edc8.jpg?v=1786026609"},{"product_id":"cable-electrique-acwu90-4-c-300-mcm-600-v-noir-acwu4c300-wire-acwu4c300","title":"Electrical Cable ACWU90 4 C 300 MCM 600 V Black ACWU4C300","description":"","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971809599599,"sku":"WIRE-ACWU4C300","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/ACWU4C300_1_20-_20746f434f-868e-4f2d-81ab-967f89fa3792.jpg?v=1786026609"},{"product_id":"cable-electrique-acwu90-4-c-6-awg-600-v-noir-acwu4c6-wire-acwu4c6","title":"Electrical Cable ACWU90 4 C 6 AWG 600 V Black ACWU4C6","description":"ARMOURED CABLE FOR COMMERCIAL, INDUSTRIAL \u0026 APARTMENT USE\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5811 01\u003cbr\u003eFour aluminum conductor material (ACM) conductors with low temperature EXELENE* cross-linked polyethylene insulation (RW90 XLPE) and bare copper bonding wire. Conductor assembly paper wrapped. Rated 600 volts. LEAD FREE and RoHS compliant. Limited Smoke Zero Halogen - CSA rated ST1 per CSA 22.2 No. 2556. Meets the FT4 flame spread test.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eFor open and concealed wiring in dry locations only.\u003cbr\u003eFor use in cabletroughs and ventilated flexible cableways in dry locations only.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C. Approved for use with ceiling fixtures.\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Aluminum\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971809894511,"sku":"WIRE-ACWU4C6","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/ACWU4C6_1_20-_202054d195-eed1-46fe-be67-1322af00edc8.jpg?v=1786026610"},{"product_id":"cable-electrique-nmwu-3-c-12-awg-300-v-noir-75-m-nmwu3c12x75-wire-nmwu3c12x75","title":"Electrical Cable NMWU 3 C 12 AWG 300 V Black 75 m NMWU3C12X75","description":"NMWU SUPERVEX 300 Volts 60ºC\u003cbr\u003e\u003cbr\u003eCSA File LL23462 Class 5821 02\u003cbr\u003eThree copper conductors with extra thickness of 60°C PVC insulation. Bare bonding wire and an overall sunlight resistant PVC jacket. Rated 300 volts. For direct earth burial (with protection as required by the inspection authority).\u003cbr\u003eFor wiring exposed to the weather. \u003cbr\u003eFor Category 1 and 2 locations (Ref. CE Code Part 1 Section 22) including barns, stables, etc.\u003cbr\u003eFor open and concealed wiring in wet or dry locations where not exposed to mechanical injury.\u003cbr\u003eMinimum recommended handling temperature minus 25°C (except for 3 conductor cables at minus 10°C) with suitable handling procedures.\u003cbr\u003eMaximum conductor temperature 60°C.\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 300 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 60 °C\u003cbr\u003e\u003cbr\u003eJacket Colours: Black is standard and is sunlight resistant.\u003cbr\u003eWhite jackets are available on request. these can be sunlight resistant, if required.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971809861743,"sku":"WIRE-NMWU3C12X75","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/NMWU3C12X75_1_20-_20804d0a57-516b-4e16-9dd0-6ec3f7a32e2b.jpg?v=1786026610"},{"product_id":"fil-electrique-de-cuivre-nu-bare-cuivre-1-0-awg-bare1-0-wire-bare1-0","title":"Electrical Wire BARE Copper 1\/0 AWG  BARE1\/0","description":"Soft Bare Copper Conductors\u003cbr\u003e\u003cbr\u003eASTM B-3 Soft or Annealed Copper Wire. ASTM B-3 Specification details the requirements for solid wires and the individual wires in stranded conductors.\u003cbr\u003eASTM B-8 Concentric - Lay - Stranded Copper Conductors\u003cbr\u003eSolid or stranded 100% conductivity copper conductors.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eUsed for bonding and grounding electrical circuits and systems.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971809927279,"sku":"WIRE-BARE1\/0","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/0_1_20-_208b4ef81f-778c-405e-8c3c-6e3cb27fd61f.jpg?v=1786026609"},{"product_id":"fil-electrique-rw90-12-awg-toronne-600-v-jaune-300-m-rw12stryelx300-wire-rw12stryelx300","title":"Electrical Wire RW90 12 AWG Stranded 600 V Yellow 300 m RW12STRYELX300","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5832 03\u003cbr\u003eSingle solid or compressed stranded (Class B) copper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810189423,"sku":"WIRE-RW12STRYELX300","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/RW12STRYELX300_1_20-_20ec731fee-13bc-408f-8f28-5371a3b84db6.jpg?v=1786026609"},{"product_id":"cable-electrique-nmwu-3-c-10-awg-300-v-noir-75-m-nmwu3c10x75-wire-nmwu3c10x75","title":"Electrical Cable NMWU 3 C 10 AWG 300 V Black 75 m NMWU3C10X75","description":"NMWU SUPERVEX 300 Volts 60ºC\u003cbr\u003e\u003cbr\u003eCSA File LL23462 Class 5821 02\u003cbr\u003eThree copper conductors with extra thickness of 60°C PVC insulation. Bare bonding wire and an overall sunlight resistant PVC jacket. Rated 300 volts. For direct earth burial (with protection as required by the inspection authority).\u003cbr\u003eFor wiring exposed to the weather. \u003cbr\u003eFor Category 1 and 2 locations (Ref. CE Code Part 1 Section 22) including barns, stables, etc.\u003cbr\u003eFor open and concealed wiring in wet or dry locations where not exposed to mechanical injury.\u003cbr\u003eMinimum recommended handling temperature minus 25°C (except for 3 conductor cables at minus 10°C) with suitable handling procedures.\u003cbr\u003eMaximum conductor temperature 60°C.\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 300 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 60 °C\u003cbr\u003e\u003cbr\u003eJacket Colours: Black is standard and is sunlight resistant.\u003cbr\u003eWhite jackets are available on request. these can be sunlight resistant, if required.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971809992815,"sku":"WIRE-NMWU3C10X75","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/NMWU3C10X75_1_20-_20804d0a57-516b-4e16-9dd0-6ec3f7a32e2b.jpg?v=1786026610"},{"product_id":"cable-electrique-acwu90-4-c-2-0-awg-600-v-noir-acwu4c2-0-wire-acwu4c2-0","title":"Electrical Cable ACWU90 4 C 2\/0 AWG 600 V Black ACWU4C2\/0","description":"ARMOURED CABLE FOR COMMERCIAL, INDUSTRIAL \u0026 APARTMENT USE\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5811 01\u003cbr\u003eFour aluminum conductor material (ACM) conductors with low temperature EXELENE* cross-linked polyethylene insulation (RW90 XLPE) and bare copper bonding wire. Conductor assembly paper wrapped. Rated 600 volts. LEAD FREE and RoHS compliant. Limited Smoke Zero Halogen - CSA rated ST1 per CSA 22.2 No. 2556. Meets the FT4 flame spread test.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eFor open and concealed wiring in dry locations only.\u003cbr\u003eFor use in cabletroughs and ventilated flexible cableways in dry locations only.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C. Approved for use with ceiling fixtures.\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Aluminum\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810254959,"sku":"WIRE-ACWU4C2\/0","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/0_1_20-_202054d195-eed1-46fe-be67-1322af00edc8_55ad2892-e882-4fa7-85a1-7c9e21b4e81f.jpg?v=1786026610"},{"product_id":"fil-electrique-rwu90-12-awg-toronne-1000-v-rouge-300-m-rwu12strredx300-wire-rwu12strredx300","title":"Electrical Wire RWU90 12 AWG Stranded 1000 V Red 300 m RWU12STRREDX300","description":"INSTAGLIDE® RWU90 (–40°C) EXELENE® XLPE Underground Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCompact stranded copper conductor material (ACM) per ASTM B801 Class B or ASTM B836 (Single Input Wire) with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. Rated 1000 volts.\u003cbr\u003eRoHS compliant.\u003cbr\u003eFor direct earth burial (with protection as required by inspecting authority - direct buried installations must comply with CE Code Rules 12-012 and 4-004). For exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 8 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT. For service entrance above or below ground.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810025583,"sku":"WIRE-RWU12STRREDX300","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/RWU12STRREDX300_1_20-_20018adac3-c8e5-4fe6-915e-7a31cd962deb.jpg?v=1786026610"},{"product_id":"fil-electrique-de-cuivre-nu-bare-cuivre-4-awg-bare4-wire-bare4","title":"Electrical Wire BARE Copper 4 AWG  BARE4","description":"Soft Bare Copper Conductors\u003cbr\u003e\u003cbr\u003eASTM B-3 Soft or Annealed Copper Wire. ASTM B-3 Specification details the requirements for solid wires and the individual wires in stranded conductors.\u003cbr\u003eASTM B-8 Concentric - Lay - Stranded Copper Conductors\u003cbr\u003eSolid or stranded 100% conductivity copper conductors.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eUsed for bonding and grounding electrical circuits and systems.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810222191,"sku":"WIRE-BARE4","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-BARE4_1_20-_20b95056cf-3cd7-46c4-827a-bf0e5637193c.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-3-awg-600-v-rouge-rw3red-wire-rw3red","title":"Electrical Wire RW90 3 AWG 600 V Red RW3RED","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810353263,"sku":"WIRE-RW3RED","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW3RED_1_20-_2001a792b1-973a-4bc2-b8b7-ec0fa2d5d9da.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-6-awg-600-v-rouge-rw6red-wire-rw6red","title":"Electrical Wire RW90 6 AWG 600 V Red RW6RED","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810386031,"sku":"WIRE-RW6RED","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW6RED_1_20-_204cc3be38-ab00-48ca-9315-b139f4bc50db.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-8-awg-600-v-vert-rw8grn-wire-rw8grn","title":"Electrical Wire RW90 8 AWG 600 V Green RW8GRN","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810418799,"sku":"WIRE-RW8GRN","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW8GRN_1_20-_20ff523ed2-bea4-4df6-84f1-6a41abd482f0.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-3-awg-600-v-vert-rw3grn-wire-rw3grn","title":"Electrical Wire RW90 3 AWG 600 V Green RW3GRN","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810451567,"sku":"WIRE-RW3GRN","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW3GRN_1_20-_20c02e8dc7-7892-457c-8e52-650ab0ff0a79.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-6-awg-600-v-blanc-rw6wht-wire-rw6wht","title":"Electrical Wire RW90 6 AWG 600 V White RW6WHT","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810484335,"sku":"WIRE-RW6WHT","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW6WHT_1_20-_208f53116f-4d59-416f-844d-3f22cce73ed5.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-8-awg-600-v-rouge-rw8red-wire-rw8red","title":"Electrical Wire RW90 8 AWG 600 V Red RW8RED","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810615407,"sku":"WIRE-RW8RED","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW8RED_1_20-_206b409d3d-7cba-420e-a495-2acf526b19bd.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-6-awg-600-v-bleu-rw6blu-wire-rw6blu","title":"Electrical Wire RW90 6 AWG 600 V Blue RW6BLU","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810680943,"sku":"WIRE-RW6BLU","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW6BLU_1_20-_20dcdf465c-3044-4537-9d4e-930855cebea1.jpg?v=1786026610"},{"product_id":"fil-electrique-t90-6-awg-600-v-blanc-t906wht-wire-t906wht","title":"Electrical Wire T90 6 AWG 600 V White T906WHT","description":"PVC Insulated Nylon Covered Cables\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5832 02\u003cbr\u003eU.L. Standard #83 - U.L. Approval # E70347\u003cbr\u003eSingle copper conductor with thin wall PVC insulation and nylon covering with FT1 rating. Rated 600 volts. LEAD FREE.\u003cbr\u003e Nexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eGeneral purpose building wire for installation as exposed or concealed wiring and in raceways (except cable trays) in dry or damp locations.\u003cbr\u003eMinimum recommended installation temperature minus 10°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C dry, 75°C in wet locations, and 60°C when exposed to oil.\u003cbr\u003eApproved for use with ceiling fixtures.\u003cbr\u003eNexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eHarmonized Product Print Legend:\u003cbr\u003eE53058 F INSTAGLIDE® 2\/0 AWG (67.4mm²) (UL) THHN OR THWN-2 OR GR II\u003cbr\u003eOR MTW 600 VOLT VW-1 CT USE MADE IN CANADA LL 23462 2\/0 AWG CSA\/\u003cbr\u003eACNOR T90 \/ TWN75 NYLON FT1\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810517103,"sku":"WIRE-T906WHT","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-T906WHT_1_20-_205e1ce66c-e74a-4c56-bd79-181cabb97c77.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-1-0-awg-600-v-vert-rw1-0grn-wire-rw1-0grn","title":"Electrical Wire RW90 1\/0 AWG 600 V Green RW1\/0GRN","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810549871,"sku":"WIRE-RW1\/0GRN","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/0GRN_1_20-_204bdbc196-4499-44e3-bd9e-9d09bc0bb916.jpg?v=1786026610"},{"product_id":"fil-electrique-t90-8-awg-600-v-vert-t908grn-wire-t908grn","title":"Electrical Wire T90 8 AWG 600 V Green T908GRN","description":"PVC Insulated Nylon Covered Cables\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5832 02\u003cbr\u003eU.L. Standard #83 - U.L. Approval # E70347\u003cbr\u003eSingle copper conductor with thin wall PVC insulation and nylon covering with FT1 rating. Rated 600 volts. LEAD FREE.\u003cbr\u003e Nexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eGeneral purpose building wire for installation as exposed or concealed wiring and in raceways (except cable trays) in dry or damp locations.\u003cbr\u003eMinimum recommended installation temperature minus 10°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C dry, 75°C in wet locations, and 60°C when exposed to oil.\u003cbr\u003eApproved for use with ceiling fixtures.\u003cbr\u003eNexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eHarmonized Product Print Legend:\u003cbr\u003eE53058 F INSTAGLIDE® 2\/0 AWG (67.4mm²) (UL) THHN OR THWN-2 OR GR II\u003cbr\u003eOR MTW 600 VOLT VW-1 CT USE MADE IN CANADA LL 23462 2\/0 AWG CSA\/\u003cbr\u003eACNOR T90 \/ TWN75 NYLON FT1\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810582639,"sku":"WIRE-T908GRN","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-T908GRN_1_20-_20c463ee49-1ce3-475e-bfba-5db57f06e7bd.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-3-awg-600-v-bleu-rw3blu-wire-rw3blu","title":"Electrical Wire RW90 3 AWG 600 V Blue RW3BLU","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810713711,"sku":"WIRE-RW3BLU","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW3BLU_1_20-_205dad9e13-bdf3-4217-b226-df71fe4251ba.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-8-awg-600-v-bleu-rw8blu-wire-rw8blu","title":"Electrical Wire RW90 8 AWG 600 V Blue RW8BLU","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971811565679,"sku":"WIRE-RW8BLU","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW8BLU_1_20-_20ec6836cf-f61a-4fe7-8616-f086a2160ec7.jpg?v=1786026610"},{"product_id":"fil-electrique-rw90-2-awg-600-v-blanc-rw2wht-wire-rw2wht","title":"Electrical Wire RW90 2 AWG 600 V White RW2WHT","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810779247,"sku":"WIRE-RW2WHT","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW2WHT_1_20-_20e4df508f-9693-41a4-987d-1565186973c2.jpg?v=1786026610"},{"product_id":"fil-electrique-t90-8-awg-600-v-blanc-t908wht-wire-t908wht","title":"Electrical Wire T90 8 AWG 600 V White T908WHT","description":"PVC Insulated Nylon Covered Cables\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5832 02\u003cbr\u003eU.L. Standard #83 - U.L. Approval # E70347\u003cbr\u003eSingle copper conductor with thin wall PVC insulation and nylon covering with FT1 rating. Rated 600 volts. LEAD FREE.\u003cbr\u003e Nexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eGeneral purpose building wire for installation as exposed or concealed wiring and in raceways (except cable trays) in dry or damp locations.\u003cbr\u003eMinimum recommended installation temperature minus 10°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C dry, 75°C in wet locations, and 60°C when exposed to oil.\u003cbr\u003eApproved for use with ceiling fixtures.\u003cbr\u003eNexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eHarmonized Product Print Legend:\u003cbr\u003eE53058 F INSTAGLIDE® 2\/0 AWG (67.4mm²) (UL) THHN OR THWN-2 OR GR II\u003cbr\u003eOR MTW 600 VOLT VW-1 CT USE MADE IN CANADA LL 23462 2\/0 AWG CSA\/\u003cbr\u003eACNOR T90 \/ TWN75 NYLON FT1\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971811532911,"sku":"WIRE-T908WHT","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-T908WHT_1_20-_20d44d11e6-0ab9-437b-9ed5-9a405b111c8b.jpg?v=1786026610"},{"product_id":"fil-electrique-t90-6-awg-600-v-vert-t906grn-wire-t906grn","title":"Electrical Wire T90 6 AWG 600 V Green T906GRN","description":"PVC Insulated Nylon Covered Cables\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5832 02\u003cbr\u003eU.L. Standard #83 - U.L. Approval # E70347\u003cbr\u003eSingle copper conductor with thin wall PVC insulation and nylon covering with FT1 rating. Rated 600 volts. LEAD FREE.\u003cbr\u003e Nexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eGeneral purpose building wire for installation as exposed or concealed wiring and in raceways (except cable trays) in dry or damp locations.\u003cbr\u003eMinimum recommended installation temperature minus 10°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C dry, 75°C in wet locations, and 60°C when exposed to oil.\u003cbr\u003eApproved for use with ceiling fixtures.\u003cbr\u003eNexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eHarmonized Product Print Legend:\u003cbr\u003eE53058 F INSTAGLIDE® 2\/0 AWG (67.4mm²) (UL) THHN OR THWN-2 OR GR II\u003cbr\u003eOR MTW 600 VOLT VW-1 CT USE MADE IN CANADA LL 23462 2\/0 AWG CSA\/\u003cbr\u003eACNOR T90 \/ TWN75 NYLON FT1\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971810844783,"sku":"WIRE-T906GRN","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-T906GRN_1_20-_2086ee1657-4a16-49e4-a336-8c82ad0e7bc9.jpg?v=1786026610"},{"product_id":"fil-electrique-t90-8-awg-600-v-noir-t908blk-wire-t908blk","title":"Electrical Wire T90 8 AWG 600 V Black T908BLK","description":"PVC Insulated Nylon Covered Cables\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5832 02\u003cbr\u003eU.L. Standard #83 - U.L. Approval # E70347\u003cbr\u003eSingle copper conductor with thin wall PVC insulation and nylon covering with FT1 rating. Rated 600 volts. LEAD FREE.\u003cbr\u003e Nexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eGeneral purpose building wire for installation as exposed or concealed wiring and in raceways (except cable trays) in dry or damp locations.\u003cbr\u003eMinimum recommended installation temperature minus 10°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C dry, 75°C in wet locations, and 60°C when exposed to oil.\u003cbr\u003eApproved for use with ceiling fixtures.\u003cbr\u003eNexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eHarmonized Product Print Legend:\u003cbr\u003eE53058 F INSTAGLIDE® 2\/0 AWG (67.4mm²) (UL) THHN OR THWN-2 OR GR II\u003cbr\u003eOR MTW 600 VOLT VW-1 CT USE MADE IN CANADA LL 23462 2\/0 AWG CSA\/\u003cbr\u003eACNOR T90 \/ TWN75 NYLON FT1\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":53971811696751,"sku":"WIRE-T908BLK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-T908BLK_1_20-_20c15ad437-6133-4851-8091-4fdbffdd452d.jpg?v=1786026610"},{"product_id":"fil-electrique-de-cuivre-nu-bare-cuivre-3-0-awg-bare3-0-wire-bare3-0","title":"Electrical Wire BARE Copper 3\/0 AWG  BARE3\/0","description":"Soft Bare Copper Conductors\u003cbr\u003e\u003cbr\u003eASTM B-3 Soft or Annealed Copper Wire. ASTM B-3 Specification details the requirements for solid wires and the individual wires in stranded conductors.\u003cbr\u003eASTM B-8 Concentric - Lay - Stranded Copper Conductors\u003cbr\u003eSolid or stranded 100% conductivity copper conductors.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eUsed for bonding and grounding electrical circuits and systems.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022241189999,"sku":"WIRE-BARE3\/0","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/0_1_20-_20a84409eb-4d5c-4203-b38d-3bd202945798.jpg?v=1786556841"},{"product_id":"fil-electrique-t90-1-0-awg-600-v-noir-t901-0blk-wire-t901-0blk","title":"Electrical Wire T90 1\/0 AWG 600 V Black T901\/0BLK","description":"PVC Insulated Nylon Covered Cables\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5832 02\u003cbr\u003eU.L. Standard #83 - U.L. Approval # E70347\u003cbr\u003eSingle copper conductor with thin wall PVC insulation and nylon covering with FT1 rating. Rated 600 volts. LEAD FREE.\u003cbr\u003e Nexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eGeneral purpose building wire for installation as exposed or concealed wiring and in raceways (except cable trays) in dry or damp locations.\u003cbr\u003eMinimum recommended installation temperature minus 10°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C dry, 75°C in wet locations, and 60°C when exposed to oil.\u003cbr\u003eApproved for use with ceiling fixtures.\u003cbr\u003eNexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eHarmonized Product Print Legend:\u003cbr\u003eE53058 F INSTAGLIDE® 2\/0 AWG (67.4mm²) (UL) THHN OR THWN-2 OR GR II\u003cbr\u003eOR MTW 600 VOLT VW-1 CT USE MADE IN CANADA LL 23462 2\/0 AWG CSA\/\u003cbr\u003eACNOR T90 \/ TWN75 NYLON FT1\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022242631791,"sku":"WIRE-T901\/0BLK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/0BLK_1_20-_208db3bc48-559f-4ba7-9f48-8b092758f33e.jpg?v=1786556857"},{"product_id":"fil-electrique-rw90-2-awg-aluminium-600v-vert-rw2grnalu-wire-rw2grnalu","title":"Electrical Wire RW90 2 AWG Aluminum 600 V Green RW2GRNALU","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eAluminum conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022242664559,"sku":"WIRE-RW2GRNALU","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW2GRNALU_1_20-_20835b34b0-9b1d-4a16-b746-a4c0e0328253.jpg?v=1786556857"},{"product_id":"cable-electrique-teck-3-c-1-0-awg-1000-v-noir-teck3c1-01kv-wire-teck3c1-01kv","title":"Electrical Cable TECK 3 C 1\/0 AWG 1000 V Black TECK3C1\/01KV","description":"Nexans FIREX®-II TECK90 Cables are intended for use in various primary and secondary industries, including chemical processing plants, refineries and general factory environments.\u003cbr\u003eDescription:\u003cbr\u003eEven in the most demanding industrial and resource industry applications,\u003cbr\u003eNexans FIREX®-II TECK90 cables have proven to have a superior service and maintenance record.\u003cbr\u003eFIREX®-II TECK90 Cables utilize low acid gas, low flame spread PVC jacket compounds to ensure maximum safety to personnel and equipment in the event of fire.\u003cbr\u003e\u003cbr\u003eApplications\u003cbr\u003eFIREX®-II TECK90 Cables, originally developed for use in Canadian mines, are flexible, resistant to mechanical abuse, corrosion resistant, compact and reliable.\u003cbr\u003eThey are suitable for a wide range of applications, including ALL hazardous locations.\u003cbr\u003eIndustries such as pulp and paper, chemical, petroleum and other primary and secondary manufacturing industries have used FIREX®-II TECK90 Cables, particularly in areas where cables are subject to the risk of mechanical damage and chemical attack.\u003cbr\u003eCommercial applications for FIREX®-II TECK90 Cables include apartment buildings and commercial complexes.\u003cbr\u003eFIREX®-II TECK90 Cables can be relocated easily because they are rugged and flexible. They can be used in both dry and wet locations in open wiring, in ventilated, non-ventilated and ladder-type cable troughs, in ventilated flexible cableways, and for direct burial.\u003cbr\u003eTECK90 Cables are also suitable for service entrance installations - above and below ground.\u003cbr\u003eHighlights\u003cbr\u003eNexans FIREX®-II TECK90 Cables are:\u003cbr\u003e• Available from stock\u003cbr\u003e• Versatile\u003cbr\u003e• Flexible\u003cbr\u003e• Resistant to Mechanical Abuse and Corrosion\u003cbr\u003e• Compact and Reliable\u003cbr\u003e• \"HL\" and \"FT4\" Rated per CSA\u003cbr\u003e• 90°C to -40°C\u003cbr\u003e• Low Acid Gas (AG14)\u003cbr\u003e• Inner and outer jackets are sunlight resistant\u003cbr\u003e• LEAD FREE\u003cbr\u003e• RoHS compliant","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022469877871,"sku":"WIRE-TECK3C1\/01KV","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-TECK3C1_01KV_1_20-_20ed946ac5-2107-4332-9562-a4d34d645c98.jpg?v=1786986421"},{"product_id":"fil-electrique-rw90-14-awg-toronne-600-v-jaune-300-m-rw14stryelx300-wire-rw14stryelx300","title":"Electrical Wire RW90 14 AWG Stranded 600 V Yellow 300 m RW14STRYELX300","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5832 03\u003cbr\u003eCompressed stranded (Class B) copper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003e\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022469910639,"sku":"WIRE-RW14STRYELX300","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/RW14STRYELX300_1_20-_20ec731fee-13bc-408f-8f28-5371a3b84db6.jpg?v=1786986397"},{"product_id":"cable-electrique-soow-4-c-12-awg-600-v-noir-soow4c12-wire-soow4c12","title":"Electrical Cable SOOW 4 C 12 AWG 600 V Black SOOW4C12","description":"","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022470533231,"sku":"WIRE-SOOW4C12","price":0.0,"currency_code":"CAD","in_stock":true}]},{"product_id":"cable-electrique-nmd90-2-c-14-awg-300-v-bleu-75-m-nmd2c14blux75-wire-nmd2c14blux75","title":"Electrical Cable NMD90 2 C 14 AWG 300 V Blue 75 m NMD2C14BLUX75","description":"CSA File #LL23462 Class 5821 02\u003cbr\u003eTwo copper conductors with 90ºC PVC Nylon T90 Nylon insulation. Bare bonding wire and overall jacket of moisture resistant and flame retardant PVC, with FT1 rating.\u003cbr\u003eRated 300 volts. RoHS compliant.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eFor open or concealed wiring in dry or damp locations where not exposed to mechanical injury.\u003cbr\u003eMinimum recommended handling temperature minus 25°C for 2 conductor cables.\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures.\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 300 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022470107247,"sku":"WIRE-NMD2C14BLUX75","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-NMD2C14BLUX75_1_20-_20ea5c7230-269f-4e84-be98-1fcaf6585690.jpg?v=1786986385"},{"product_id":"cable-electrique-teck-2-c-6-awg-1000-v-noir-teck2c61kv-wire-teck2c61kv","title":"Electrical Cable TECK 2 C 6 AWG 1000 V Black TECK2C61KV","description":"Nexans FIREX®-II TECK90 Cables are intended for use in various primary and secondary industries, including chemical processing plants, refineries and general factory environments.\u003cbr\u003eDescription:\u003cbr\u003eEven in the most demanding industrial and resource industry applications,\u003cbr\u003eNexans FIREX®-II TECK90 cables have proven to have a superior service and maintenance record.\u003cbr\u003eFIREX®-II TECK90 Cables utilize low acid gas, low flame spread PVC jacket compounds to ensure maximum safety to personnel and equipment in the event of fire.\u003cbr\u003e\u003cbr\u003eApplications\u003cbr\u003eFIREX®-II TECK90 Cables, originally developed for use in Canadian mines, are flexible, resistant to mechanical abuse, corrosion resistant, compact and reliable.\u003cbr\u003eThey are suitable for a wide range of applications, including ALL hazardous locations.\u003cbr\u003eIndustries such as pulp and paper, chemical, petroleum and other primary and secondary manufacturing industries have used FIREX®-II TECK90 Cables, particularly in areas where cables are subject to the risk of mechanical damage and chemical attack.\u003cbr\u003eCommercial applications for FIREX®-II TECK90 Cables include apartment buildings and commercial complexes.\u003cbr\u003eFIREX®-II TECK90 Cables can be relocated easily because they are rugged and flexible. They can be used in both dry and wet locations in open wiring, in ventilated, non-ventilated and ladder-type cable troughs, in ventilated flexible cableways, and for direct burial.\u003cbr\u003eTECK90 Cables are also suitable for service entrance installations - above and below ground.\u003cbr\u003eHighlights\u003cbr\u003eNexans FIREX®-II TECK90 Cables are:\u003cbr\u003e• Available from stock\u003cbr\u003e• Versatile\u003cbr\u003e• Flexible\u003cbr\u003e• Resistant to Mechanical Abuse and Corrosion\u003cbr\u003e• Compact and Reliable\u003cbr\u003e• \"HL\" and \"FT4\" Rated per CSA\u003cbr\u003e• 90°C to -40°C\u003cbr\u003e• Low Acid Gas (AG14)\u003cbr\u003e• Inner and outer jackets are sunlight resistant\u003cbr\u003e• LEAD FREE\u003cbr\u003e• RoHS compliant","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022475579503,"sku":"WIRE-TECK2C61KV","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-TECK2C61KV_1_20-_2059cf7545-9aff-4c87-810b-dc7a0a0052a5.jpg?v=1786986409"},{"product_id":"fil-electrique-de-soudage-welding-2-0-awg-600-v-rouge-welding1c2-0red-wire-welding1c2-0red","title":"Electrical Wire WELDING 2\/0 AWG 600 V Red WELDING1C2\/0RED","description":"Welding Cables are used for Secondary voltage resistance welding leads. Power supply applications not exceeding 600 volts AC.\u003cbr\u003e\u003cbr\u003eSPECIFICATIONS\u003cbr\u003e• ASTM B-3\u003cbr\u003e• ASTM B-172\u003cbr\u003e• RoHS Compliant\u003cbr\u003e• ICEA S-75-381\u003cbr\u003e\u003cbr\u003eCONSTRUCTION\u003cbr\u003eSouthwire Welding Cables are manufactured using annealed rope-stranded bare copper conductor as per ICEA\u003cbr\u003eS-75-381. A paper tape separates the conductor from the insulation to facilitate stripping. A 105° EPDM black\u003cbr\u003ejacket is extruded onto the cable.\u003cbr\u003e\u003cbr\u003eALTERNATE CONSTRUCTION\u003cbr\u003eAlso available with a red jacket. May be subject to minimum order.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022474793071,"sku":"WIRE-WELDING1C2\/0RED","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/0RED_1_20-_20fb19fc2c-f71e-487a-995b-92f2be26c389.jpg?v=1786987301"},{"product_id":"cable-electrique-soow-3-c-12-awg-600-v-noir-76-m-soow3c12x76-wire-soow3c12x76","title":"Electrical Cable SOOW 3 C 12 AWG 600 V Black 76 m SOOW3C12X76","description":"Rubber Cord,90ºC, 600 Volt, UL\/CSA Portable Cord, Product Construction:\u003cbr\u003eConductors:\u003cbr\u003e• 18 and 16 AWG fully annealed stranded bare copper\u003cbr\u003eInsulation:\u003cbr\u003e• Premium-grade, color-coded 90ºC EPDM\u003cbr\u003e• Color code: See chart below\u003cbr\u003eJacket:\u003cbr\u003e• Super Vu-Tron® 90ºC, black\u003cbr\u003e• Temperature range: -40ºC to +90ºC\u003cbr\u003eJacket Marking:\u003cbr\u003e• CAROL SUPER VU-TRON® (SIZE) (mm2) 90°C (UL) WATER RESISTANT SOOW CSA (-40°C) FT2 P-7K-123033 MSHA 600 VOLT ROHS\u003cbr\u003eMADE IN USA\u003cbr\u003eApplications: • Control circuits\u003cbr\u003e• Tools\u003cbr\u003e• Heavy industrial, processing and construction equipment\u003cbr\u003eFeatures: • Extra-flexible stranding\u003cbr\u003e• Abrasion-resistant\u003cbr\u003e• Resists oils and solvents\u003cbr\u003e• Flame-resistant\u003cbr\u003e• Ozone-resistant\u003cbr\u003e• 90ºC rated conductors and jacket\u003cbr\u003e• Water-resistant*\u003cbr\u003e• UL Listed and CSA Certified for indoor and outdoor use\u003cbr\u003e• Ozone-, sunlight (UV)- and weather-resistant\u003cbr\u003eIndustry Approvals: • UL Flexible Cord - UL 62\u003cbr\u003e• CSA Flexible Cord - C22.2-49\u003cbr\u003e• MSHA Approved\u003cbr\u003e• RoHS Compliant\u003cbr\u003ePackaging: • 5- through 8-conductor available on 250'\u003cbr\u003e(76.2 m), 500' (152.4 m), and 1000' (304.8 m) reels\u003cbr\u003e• 9+ cond. available on long-length reels\u003cbr\u003e• Other put-ups available on special order\u003cbr\u003e* Suitable for immersion in water if properly sealed and\u003cbr\u003eterminated.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022479675503,"sku":"WIRE-SOOW3C12X76","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/SOOW3C12X76_1_20-_200e911bef-7e96-48a0-a8ff-fb87c06e3f3c.jpg?v=1786986385"},{"product_id":"fil-electrique-rw90-10-awg-toronne-600-v-noir-300-m-rw10strblkx300-wire-rw10strblkx300","title":"Electrical Wire RW90 10 AWG Stranded 600 V Black 300 m RW10STRBLKX300","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5832 03\u003cbr\u003eSingle solid or compressed stranded (Class B) copper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene\u003cbr\u003e(XLPE) insulation. RoHS compliant.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022478725231,"sku":"WIRE-RW10STRBLKX300","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW10STRBLKX300_1_20-_20423fd4be-aab7-4417-9c8f-37177b5aa6c5.jpg?v=1786986398"},{"product_id":"fil-electrique-de-soudage-welding-4-0-awg-600-v-noir-welding1c4-0blk-wire-welding1c4-0blk","title":"Electrical Wire WELDING 4\/0 AWG 600 V Black WELDING1C4\/0BLK","description":"Welding Cables are used for Secondary voltage resistance welding leads. Power supply applications not exceeding 600 volts AC.\u003cbr\u003e\u003cbr\u003eSPECIFICATIONS\u003cbr\u003e• ASTM B-3\u003cbr\u003e• ASTM B-172\u003cbr\u003e• RoHS Compliant\u003cbr\u003e• ICEA S-75-381\u003cbr\u003e\u003cbr\u003eCONSTRUCTION\u003cbr\u003eSouthwire Welding Cables are manufactured using annealed rope-stranded bare copper conductor as per ICEA\u003cbr\u003eS-75-381. A paper tape separates the conductor from the insulation to facilitate stripping. A 105° EPDM black\u003cbr\u003ejacket is extruded onto the cable.\u003cbr\u003e\u003cbr\u003eALTERNATE CONSTRUCTION\u003cbr\u003eAlso available with a red jacket. May be subject to minimum order.","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022478823535,"sku":"WIRE-WELDING1C4\/0BLK","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/0BLK_1_20-_20ff8e0e18-cd3b-49a8-a8ff-a1239cb9a2ab_8063daaf-e0a4-471c-9b82-c2e8513233b8.jpg?v=1786986433"},{"product_id":"cable-electrique-ac90-3-c-10-awg-600-v-150-m-ac3c10x150-wire-ac3c10x150","title":"Electrical Cable AC90 3 C 10 AWG 600 V 150 m AC3C10X150","description":"ARMOURED CABLE FOR COMMERCIAL, INDUSTRIAL \u0026 APARTMENT USE\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5811 01\u003cbr\u003eTHREE copper conductor material (ACM) conductors with low temperature EXELENE* cross-linked polyethylene insulation (RW90 XLPE) and\u003cbr\u003ebare copper bonding wire. Conductor assembly paper wrapped and covered with bare interlocked aluminum armour. Rated 600 volts. LEAD FREE\u003cbr\u003eand RoHS compliant. Limited Smoke Zero Halogen - CSA rated ST1 per CSA 22.2 No. 2556. Meets the FT4 flame spread test.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eFor open and concealed wiring in dry locations only.\u003cbr\u003eFor use in cabletroughs and ventilated flexible cableways in dry locations only.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C. Approved for use with ceiling fixtures.\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022479249519,"sku":"WIRE-AC3C10X150","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-AC3C10X150_1_20-_20b8ddce49-412d-43e1-9615-4755d4e2a14f.jpg?v=1786986360"},{"product_id":"cable-electrique-acwu90-3-c-300-mcm-600-v-noir-acwu3c300-wire-acwu3c300","title":"Electrical Cable ACWU90 3 C 300 MCM 600 V Black ACWU3C300","description":"ARMOURED CABLE FOR COMMERCIAL, INDUSTRIAL \u0026 APARTMENT USE\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5811 01\u003cbr\u003eThree aluminum conductor material (ACM) conductors with low temperature EXELENE* cross-linked polyethylene insulation (RW90 XLPE) and bare copper bonding wire. Conductor assembly paper wrapped. Rated 600 volts. LEAD FREE and RoHS compliant. Limited Smoke Zero Halogen - CSA rated ST1 per CSA 22.2 No. 2556. Meets the FT4 flame spread test.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eFor open and concealed wiring in dry locations only.\u003cbr\u003eFor use in cabletroughs and ventilated flexible cableways in dry locations only.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C. Approved for use with ceiling fixtures.\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Aluminum\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022478954607,"sku":"WIRE-ACWU3C300","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-ACWU3C300_1_20-_20ae4bb2bd-e06e-45da-8b81-38aae93caeff.jpg?v=1786986373"},{"product_id":"fil-electrique-rw90-2-awg-600-v-vert-rw2grn-wire-rw2grn","title":"Electrical Wire RW90 2 AWG 600 V Green RW2GRN","description":"INSTAGLIDE® RW90 (–40°C) EXELENE® XLPE 600 V Copper Service Entrance and Branch Circuit Wire, CSA File #LL23462 Class 5832 03\u003cbr\u003eCopper conductor with low temperature moisture resisting EXELENE® cross-linked polyethylene (XLPE) insulation. RoHS compliant.\u003cbr\u003eFor open wiring and raceways (except cabletroughs and ventilated flexible cableway) in dry or wet locations.\u003cbr\u003eFor exposed wiring where exposed to weather with sunlight resistant insulation.\u003cbr\u003eStandard Black 6 AWG and larger is sunlight resistant and marked \"SR\"; coloured insulation is NOT.\u003cbr\u003eMinimum recommended installation temperature minus 40°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures. Nexans INSTAGLIDE® reduced friction construction in black sizes 6 AWG and larger","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022483181679,"sku":"WIRE-RW2GRN","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-RW2GRN_1_20-_203a9753ab-aa2b-4864-94a7-350f434c25aa.jpg?v=1786987313"},{"product_id":"fil-electrique-t90-8-awg-600-v-bleu-t908blu-wire-t908blu","title":"Electrical Wire T90 8 AWG 600 V Blue T908BLU","description":"PVC Insulated Nylon Covered Cables\u003cbr\u003e\u003cbr\u003eCSA File #LL23462 Class 5832 02\u003cbr\u003eU.L. Standard #83 - U.L. Approval # E70347\u003cbr\u003eSingle copper conductor with thin wall PVC insulation and nylon covering with FT1 rating. Rated 600 volts. LEAD FREE.\u003cbr\u003e Nexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eGeneral purpose building wire for installation as exposed or concealed wiring and in raceways (except cable trays) in dry or damp locations.\u003cbr\u003eMinimum recommended installation temperature minus 10°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C dry, 75°C in wet locations, and 60°C when exposed to oil.\u003cbr\u003eApproved for use with ceiling fixtures.\u003cbr\u003eNexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eHarmonized Product Print Legend:\u003cbr\u003eE53058 F INSTAGLIDE® 2\/0 AWG (67.4mm²) (UL) THHN OR THWN-2 OR GR II\u003cbr\u003eOR MTW 600 VOLT VW-1 CT USE MADE IN CANADA LL 23462 2\/0 AWG CSA\/\u003cbr\u003eACNOR T90 \/ TWN75 NYLON FT1\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022483673199,"sku":"WIRE-T908BLU","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-T908BLU_1_20-_20e04bc050-c817-4c2b-837a-0f923a8cbf2b.jpg?v=1786987313"},{"product_id":"cable-electrique-nmd90-2-c-8-awg-300-v-rouge-nmd2c8-wire-nmd2c8","title":"Electrical Cable NMD90 2 C 8 AWG 300 V Red NMD2C8","description":"CSA File #LL23462 Class 5821 02\u003cbr\u003eTwo copper conductors with 90ºC PVC Nylon T90 Nylon insulation. Bare bonding wire and overall jacket of moisture resistant and flame retardant PVC, with FT1 rating.\u003cbr\u003eRated 300 volts. RoHS compliant.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eFor open or concealed wiring in dry or damp locations where not exposed to mechanical injury.\u003cbr\u003eMinimum recommended handling temperature minus 25°C for 2 conductor cables.\u003cbr\u003eMaximum conductor temperature 90°C.\u003cbr\u003eApproved for use with ceiling fixtures.\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 300 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022484525167,"sku":"WIRE-NMD2C8","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-NMD2C8_1_20-_2064a8d148-089f-46c9-b2b4-1d57268b3221.jpg?v=1786987313"},{"product_id":"cable-electrique-teck-8-c-14-awg-600-v-noir-teck8c14-wire-teck8c14","title":"Electrical Cable TECK 8 C 14 AWG 600 V Black TECK8C14","description":"Nexans FIREX®-II TECK90 Cables are intended for use in various primary and secondary industries, including chemical processing plants, refineries and general factory environments.\u003cbr\u003eDescription:\u003cbr\u003eEven in the most demanding industrial and resource industry applications,\u003cbr\u003eNexans FIREX®-II TECK90 cables have proven to have a superior service and maintenance record.\u003cbr\u003eFIREX®-II TECK90 Cables utilize low acid gas, low flame spread PVC jacket compounds to ensure maximum safety to personnel and equipment in the event of fire.\u003cbr\u003e\u003cbr\u003eApplications\u003cbr\u003eFIREX®-II TECK90 Cables, originally developed for use in Canadian mines, are flexible, resistant to mechanical abuse, corrosion resistant, compact and reliable.\u003cbr\u003eThey are suitable for a wide range of applications, including ALL hazardous locations.\u003cbr\u003eIndustries such as pulp and paper, chemical, petroleum and other primary and secondary manufacturing industries have used FIREX®-II TECK90 Cables, particularly in areas where cables are subject to the risk of mechanical damage and chemical attack.\u003cbr\u003eCommercial applications for FIREX®-II TECK90 Cables include apartment buildings and commercial complexes.\u003cbr\u003eFIREX®-II TECK90 Cables can be relocated easily because they are rugged and flexible. They can be used in both dry and wet locations in open wiring, in ventilated, non-ventilated and ladder-type cable troughs, in ventilated flexible cableways, and for direct burial.\u003cbr\u003eTECK90 Cables are also suitable for service entrance installations - above and below ground.\u003cbr\u003eHighlights\u003cbr\u003eNexans FIREX®-II TECK90 Cables are:\u003cbr\u003e• Available from stock\u003cbr\u003e• Versatile\u003cbr\u003e• Flexible\u003cbr\u003e• Resistant to Mechanical Abuse and Corrosion\u003cbr\u003e• Compact and Reliable\u003cbr\u003e• \"HL\" and \"FT4\" Rated per CSA\u003cbr\u003e• 90°C to -40°C\u003cbr\u003e• Low Acid Gas (AG14)\u003cbr\u003e• Inner and outer jackets are sunlight resistant\u003cbr\u003e• LEAD FREE\u003cbr\u003e• RoHS compliant","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022489669743,"sku":"WIRE-TECK8C14","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-TECK8C14_1_20-_20c3e0b2c8-61b3-4244-8d4f-97b5b54bc5b3.jpg?v=1786986421"},{"product_id":"cable-electrique-teck-3-c-14-awg-600-v-noir-teck3c14-wire-teck3c14","title":"Electrical Cable TECK 3 C 14 AWG 600 V Black TECK3C14","description":"Nexans FIREX®-II TECK90 Cables are intended for use in various primary and secondary industries, including chemical processing plants, refineries and general factory environments.\u003cbr\u003eDescription:\u003cbr\u003eEven in the most demanding industrial and resource industry applications,\u003cbr\u003eNexans FIREX®-II TECK90 cables have proven to have a superior service and maintenance record.\u003cbr\u003eFIREX®-II TECK90 Cables utilize low acid gas, low flame spread PVC jacket compounds to ensure maximum safety to personnel and equipment in the event of fire.\u003cbr\u003e\u003cbr\u003eApplications\u003cbr\u003eFIREX®-II TECK90 Cables, originally developed for use in Canadian mines, are flexible, resistant to mechanical abuse, corrosion resistant, compact and reliable.\u003cbr\u003eThey are suitable for a wide range of applications, including ALL hazardous locations.\u003cbr\u003eIndustries such as pulp and paper, chemical, petroleum and other primary and secondary manufacturing industries have used FIREX®-II TECK90 Cables, particularly in areas where cables are subject to the risk of mechanical damage and chemical attack.\u003cbr\u003eCommercial applications for FIREX®-II TECK90 Cables include apartment buildings and commercial complexes.\u003cbr\u003eFIREX®-II TECK90 Cables can be relocated easily because they are rugged and flexible. They can be used in both dry and wet locations in open wiring, in ventilated, non-ventilated and ladder-type cable troughs, in ventilated flexible cableways, and for direct burial.\u003cbr\u003eTECK90 Cables are also suitable for service entrance installations - above and below ground.\u003cbr\u003eHighlights\u003cbr\u003eNexans FIREX®-II TECK90 Cables are:\u003cbr\u003e• Available from stock\u003cbr\u003e• Versatile\u003cbr\u003e• Flexible\u003cbr\u003e• Resistant to Mechanical Abuse and Corrosion\u003cbr\u003e• Compact and Reliable\u003cbr\u003e• \"HL\" and \"FT4\" Rated per CSA\u003cbr\u003e• 90°C to -40°C\u003cbr\u003e• Low Acid Gas (AG14)\u003cbr\u003e• Inner and outer jackets are sunlight resistant\u003cbr\u003e• LEAD FREE\u003cbr\u003e• RoHS compliant","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022489866351,"sku":"WIRE-TECK3C14","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-TECK3C14_1_20-_2014cfa63c-7012-4156-a039-a07d38022445.jpg?v=1786986422"},{"product_id":"cable-electrique-teck-2-c-14-awg-600-v-noir-teck2c14-wire-teck2c14","title":"Electrical Cable TECK 2 C 14 AWG 600 V Black TECK2C14","description":"Nexans FIREX®-II TECK90 Cables are intended for use in various primary and secondary industries, including chemical processing plants, refineries and general factory environments.\u003cbr\u003eDescription:\u003cbr\u003eEven in the most demanding industrial and resource industry applications,\u003cbr\u003eNexans FIREX®-II TECK90 cables have proven to have a superior service and maintenance record.\u003cbr\u003eFIREX®-II TECK90 Cables utilize low acid gas, low flame spread PVC jacket compounds to ensure maximum safety to personnel and equipment in the event of fire.\u003cbr\u003e\u003cbr\u003eApplications\u003cbr\u003eFIREX®-II TECK90 Cables, originally developed for use in Canadian mines, are flexible, resistant to mechanical abuse, corrosion resistant, compact and reliable.\u003cbr\u003eThey are suitable for a wide range of applications, including ALL hazardous locations.\u003cbr\u003eIndustries such as pulp and paper, chemical, petroleum and other primary and secondary manufacturing industries have used FIREX®-II TECK90 Cables, particularly in areas where cables are subject to the risk of mechanical damage and chemical attack.\u003cbr\u003eCommercial applications for FIREX®-II TECK90 Cables include apartment buildings and commercial complexes.\u003cbr\u003eFIREX®-II TECK90 Cables can be relocated easily because they are rugged and flexible. They can be used in both dry and wet locations in open wiring, in ventilated, non-ventilated and ladder-type cable troughs, in ventilated flexible cableways, and for direct burial.\u003cbr\u003eTECK90 Cables are also suitable for service entrance installations - above and below ground.\u003cbr\u003eHighlights\u003cbr\u003eNexans FIREX®-II TECK90 Cables are:\u003cbr\u003e• Available from stock\u003cbr\u003e• Versatile\u003cbr\u003e• Flexible\u003cbr\u003e• Resistant to Mechanical Abuse and Corrosion\u003cbr\u003e• Compact and Reliable\u003cbr\u003e• \"HL\" and \"FT4\" Rated per CSA\u003cbr\u003e• 90°C to -40°C\u003cbr\u003e• Low Acid Gas (AG14)\u003cbr\u003e• Inner and outer jackets are sunlight resistant\u003cbr\u003e• LEAD FREE\u003cbr\u003e• RoHS compliant","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022490325103,"sku":"WIRE-TECK2C14","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-TECK2C14_1_20-_2052d96a65-fcac-42bc-ad7f-336f3166cb72.jpg?v=1786986421"},{"product_id":"cable-electrique-acwu90-3-c-400-mcm-600-v-noir-acwu3c400-wire-acwu3c400","title":"Electrical Cable ACWU90 3 C 400 MCM 600 V Black ACWU3C400","description":"","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022493831279,"sku":"WIRE-ACWU3C400","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/ACWU3C400_1_20-_209d4b9cca-dbec-4442-955b-18305627cf78.jpg?v=1786986610"},{"product_id":"fil-electrique-t90-12-awg-toronne-600-v-blanc-300-m-t9012strwhtx300-wire-t9012strwhtx300","title":"Electrical Wire T90 12 AWG Stranded 600 V White 300 m T9012STRWHTX300","description":"CSA File #LL23462 Class 5832 02\u003cbr\u003eU.L. Standard #83 - U.L. Approval # E70347\u003cbr\u003e\u003cbr\u003eSingle copper conductor with thin wall PVC insulation and nylon covering with FT1 rating. Rated 600 volts. LEAD FREE. Nexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eApplication\u003cbr\u003eGeneral purpose building wire for installation as exposed or concealed wiring and in raceways (except cable trays) in dry or damp locations.\u003cbr\u003eMinimum recommended installation temperature minus 10°C (with suitable handling procedures).\u003cbr\u003eMaximum conductor temperature 90°C dry, 75°C in wet locations, and 60°C when exposed to oil.\u003cbr\u003eApproved for use with ceiling fixtures.\u003cbr\u003eNexans INSTAGLIDE® reduced friction construction in sizes 6 AWG and larger.\u003cbr\u003e\u003cbr\u003eHarmonized Product Print Legend:\u003cbr\u003eE53058 F INSTAGLIDE® 2\/0 AWG (67.4mm²) (UL) THHN OR THWN-2 OR GR II, OR MTW 600 VOLT VW-1 CT USE MADE IN CANADA LL 23462 2\/0 AWG CSA\/ ACNOR T90 \/ TWN75 NYLON FT1\u003cbr\u003e\u003cbr\u003eConstruction characteristics\u003cbr\u003eConductor material Copper\u003cbr\u003e\u003cbr\u003eElectrical characteristics\u003cbr\u003eMaximum operating voltage 600 V\u003cbr\u003e\u003cbr\u003eUsage characteristics\u003cbr\u003eMaximum operating temperature 90 °C\u003cbr\u003e\u003cbr\u003eT90 \/ TWN75 is NOT sunlight resistant","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022498025583,"sku":"WIRE-T9012STRWHTX300","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-T9012STRWHTX300_1_20-_2017b479a9-6c98-492a-a4fb-0318220b6f79.jpg?v=1786986409"},{"product_id":"cable-electrique-teck-3-c-12-awg-1000-v-noir-teck3c121kv-wire-teck3c121kv","title":"Electrical Cable TECK 3 C 12 AWG 1000 V Black TECK3C121KV","description":"Nexans FIREX®-II TECK90 Cables are intended for use in various primary and secondary industries, including chemical processing plants, refineries and general factory environments.\u003cbr\u003eDescription:\u003cbr\u003eEven in the most demanding industrial and resource industry applications,\u003cbr\u003eNexans FIREX®-II TECK90 cables have proven to have a superior service and maintenance record.\u003cbr\u003eFIREX®-II TECK90 Cables utilize low acid gas, low flame spread PVC jacket compounds to ensure maximum safety to personnel and equipment in the event of fire.\u003cbr\u003e\u003cbr\u003eApplications\u003cbr\u003eFIREX®-II TECK90 Cables, originally developed for use in Canadian mines, are flexible, resistant to mechanical abuse, corrosion resistant, compact and reliable.\u003cbr\u003eThey are suitable for a wide range of applications, including ALL hazardous locations.\u003cbr\u003eIndustries such as pulp and paper, chemical, petroleum and other primary and secondary manufacturing industries have used FIREX®-II TECK90 Cables, particularly in areas where cables are subject to the risk of mechanical damage and chemical attack.\u003cbr\u003eCommercial applications for FIREX®-II TECK90 Cables include apartment buildings and commercial complexes.\u003cbr\u003eFIREX®-II TECK90 Cables can be relocated easily because they are rugged and flexible. They can be used in both dry and wet locations in open wiring, in ventilated, non-ventilated and ladder-type cable troughs, in ventilated flexible cableways, and for direct burial.\u003cbr\u003eTECK90 Cables are also suitable for service entrance installations - above and below ground.\u003cbr\u003eHighlights\u003cbr\u003eNexans FIREX®-II TECK90 Cables are:\u003cbr\u003e• Available from stock\u003cbr\u003e• Versatile\u003cbr\u003e• Flexible\u003cbr\u003e• Resistant to Mechanical Abuse and Corrosion\u003cbr\u003e• Compact and Reliable\u003cbr\u003e• \"HL\" and \"FT4\" Rated per CSA\u003cbr\u003e• 90°C to -40°C\u003cbr\u003e• Low Acid Gas (AG14)\u003cbr\u003e• Inner and outer jackets are sunlight resistant\u003cbr\u003e• LEAD FREE\u003cbr\u003e• RoHS compliant","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022497140847,"sku":"WIRE-TECK3C121KV","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/WIRE-TECK3C121KV_1_20-_20fca300ac-aabb-4f2d-9135-8887edd58211.jpg?v=1786986410"},{"product_id":"cable-electrique-sjoow-4-c-12-awg-300-v-noir-76-m-sjoow4c12x76-wire-sjoow4c12x76","title":"Electrical Cable SJOOW 4 C 12 AWG 300 V Black 76 m SJOOW4C12X76","description":"Type SJOOW Flexible Cords are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code. Some typical applications for Type SJOOW Cords include wiring for portable tools, portable appliances,equipment, small motors and associated machinery.\u003cbr\u003eSPECIFICATIONS\u003cbr\u003e• UL 62\u003cbr\u003e• CSA Standard 22.2 No. 49\u003cbr\u003e• MSHA flame resistance for Mining Applications - PO7-KA070018-1MSHA\u003cbr\u003e• Federal Specification J-C-580B\u003cbr\u003e• NEC Article 400\u003cbr\u003e• OSHA acceptable\u003cbr\u003e• RoHS\u003cbr\u003eType SJOOW Flexible Cords are manufactured using bare flexible stranded Class K copper conductors, with a heat, moisture and oil resistant EPDM rubber insulation. The insulated conductors are cabled with wax paper fillers, with a tissue-paper separator wrapped around the assembly to promote easier removal of the jacket. A heat, moisture and oil resistant flexible CPE jacket is extruded over the assembly to complete the construction. Sizes 18 through 10 AWG fully annealed stranded bare copper per ASTM B-174. Some sizes may be subject to minimum order quantity. 90°C Cord. 300 Volts.\u003cbr\u003eGood Tensile Strength, Elongation and Aging Characteristics.\u003cbr\u003eBlack Jacket. Rated -40°C to 90°C.\u003cbr\u003eRoHS Compliant. UL Listed and CSA Certified for Indoor and Outdoor Use.\u003cbr\u003eProvides Premium Oil Resistance, Water Resistant and High Flexibility.\u003cbr\u003eExcellent Abrasion Resistance.\u003cbr\u003eNEC, Rated Hard Usage","brand":"WIRE","offers":[{"title":"Default Title","offer_id":54022501138543,"sku":"WIRE-SJOOW4C12X76","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/files\/SJOOW4C12X76_1_20-_200ee41858-0fbf-470b-a3f1-4a64d1062015.jpg?v=1786986374"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/1032\/7407\/collections\/Collection_Fils_et_cables_Dubo.jpg?v=1786635571","url":"https:\/\/www.dubo.ca\/en\/collections\/wires-cables.oembed?page=42","provider":"Dubo.ca","version":"1.0","type":"link"}